Sight Search

Newsflash! Low Pressure Hose Deterioration

DAN has learned of at least 8 or more recent cases of failure in regulators arising from the build-up of crystals in the second stage hose, where these are constructed using a polymer-braided structure. We intend to publish a more in depth account of this in the Alert Diver Magazine, written by Francois Burman, a professional engineer on the DAN staff, but this safety-related issue needs to be brought to the more urgent attention of both divers and diving equipment service providers. 
Invisible Crystals
By Francois Burman, Pr. Eng, MSc

Crystallized nylon-hose interiors can cause regulator failures. Polymorphic crystallization inside hoses has recently emerged as a hazard divers should be aware of.

Scuba equipment failure or malfunction is a relatively rare factor in diving-related accidents and fatalities. When it does occur, the most common and hazardous malfunctions involve regulators and buoyancy compensator (BC) power inflators.1 Thus, a recent report to DAN® of a regulator failure was not necessarily surprising, but the cause in this particular case turned out to be quite unusual.

Although the diver involved in the incident managed the situation very well, and no one was harmed, an inexperienced or nervous diver might not have been so fortunate. It was particularly strange that although the diver's cylinder was not empty, the gas flow had slowed and then ceased in a way that resembled an out-of-air situation. Closer examination of the equipment led to a puzzling discovery: A large amount of yellow crystallized material was blocking the inside of the braided second-stage regulator hose. The hose had been in use for a few years but showed no external abnormalities or signs of deterioration.

While trying to solve the mystery, we discovered this was not an isolated case. The same situation occurred July 22, 2015, and was reported subsequently in a technical diving blog.2 Further reports from a hose manufacturer and at least one equipment-servicing workshop in a popular diving region revealed that these were not isolated events. Although no injuries have been reported, the discovery prompted a wider, global investigation, which is ongoing.
 
Analysis revealed the culprit to be a form of polymorphic crystallization — a phenomenon associated with cyclical heating and cooling at oil-water interfaces.3 In both incidents, the crystallization seemed to be related to the molecular structure of the internal tube. The current theory is that repeated cyclical heating and cooling of the hose lining promotes this form of crystallization in materials either unsuitable for this application or affected by certain chemicals or bacteria. The sun heats the hose, then the flow of breathing gas cools down the internal surface of the hose again. This process recurs with each dive, and the crystals grow and accumulate over time. Enough crystals eventually form to encroach on the gas flow, or they migrate toward the second-stage regulator, resulting in significant failure of the breathing device.

So far the reported incidents have been in tropical climates with gear that is several years old. We have not received reports of this problem with vinyl hoses, and given the number of braided hoses out there (both as original components and replacement parts) the incidence is likely quite small. But because this hazard threatens divers' air supplies, it is of great potential interest to the dive community. The challenge is determining how best to respond to this discovery. It's important to identify what divers need to know right now as well as what precautionary maintenance guidelines and early detection strategies they should implement at this stage.

The standard safety recommendation regarding regulator hoses has been that they should be inspected regularly for signs of external deterioration. Disintegration or abrasion of the outer rubber coating eventually predisposes hoses to rupture during pressurization or even when in use. Rubber hoses are quite prone to this condition, which is why polymer-braided hoses were developed. But herein lies the problem: The outside of braided hoses can appear normal, flexible and free from obvious abnormalities, while a deteriorated internal surface would be completely invisible to a cursory external inspection.
 
It would be premature to speculate that this deterioration is limited to braided hoses. Previously, hoses comprised a rubber inner hose, a single braid layer for reinforcement and finally a rubber outer sealing layer. Today the rubber inner hose is sometimes replaced with a polyurethane or nylon hose (referred to as thermoplastic). The middle or reinforcing layer is a polymer-filament braid, and the outer layer is either a second braid — which has the advantage of indicating when the inner hose has a leak — or a polyurethane or synthetic-rubber sealing layer.

Newer second-stage hoses with a thermoplastic inner layer may be vulnerable to degradation. This risk does not apply to internal layers of synthetic rubber, which appear to be impervious to this phenomenon. DAN Research would normally wish to conduct more in-depth analysis with a wider sample of defective hoses, but because this is a potential hazard to regulator function we prefer to err on the side of caution and report this phenomenon now.
What Does DAN Recommend?

DAN has contacted manufacturers of outer braided hoses to assess possible causes and precautionary measures, and we feel it is important to advise divers as follows:

  • All regulator hoses, including braided hoses, have a limited service-life – irrespective of the external appearance, or the reinforcement and protection provided by hose protectors or the braiding itself. Prior to 2010, the stated service life of 5 years or 500 dives for braided hoses appears to be inaccurate; failures have occurred in hoses with less than 4 years of in-service life. After this date, the manufacturers appear to have made satisfactory changes.
  • The inside lining of all hoses appears to be uniquely prone to degradation in the form of 'crystallisation’, especially in hot, tropical locations. This is a gradual process, reportedly especially active in the range of 27° - 32°C, but the disruption of gas-flow and regulator function is unpredictable and invisible to external inspection.
  •  Any sign of gas-flow restriction in the regulator assembly should prompt careful inspection of the regulator and the hose. If the regulator is not the cause, suspect the hose.
  • A physical examination including squeezing the hose every couple of inches to assess whether the hoses exhibits the same degree of flex should indicate if all is well. Any indication of a change in the resistance.
Please share this information with other divers and promote diving safety through the following advice:
  • Make all divers aware of this problem and the need for regular equipment servicing.
  • Practice emergency alternative gas source sharing procedures to ensure preparedness and appropriate action in the event of regulator failure as well as out-of-gas situations.
  • Be aware of what you buy - ensure that any hose purchased clearly shows information on the manufacturer, the production date and the standard used on the ends, and check that this information is consistent with the packaging.
We invite all divers who experience this inner-hose degradation to please contact DAN (info@dansa.org), preferably with pictures showing the condition of the inner hose. This will enable us to capture as much real information as possible, so that we can learn more about this phenomenon. Any new findings, cautions or advice will be shared with the diving community. 

6 Comments


Andy - June 16th, 2016 at 6:13am

Originally brought to light in 2015 (see link)... this issue has been reported by many scuba divers. http://scubatechphilippines.com/scuba_blog/regulator-hose-diving-emergency/

Alex - July 18th, 2016 at 6:28am

Can anyone comment on the brand of hose, number of dives, diving air or EANx? Were these rental gear used every day or did they sit in someone's closet most of the time?

John Clark - January 27th, 2017 at 4:16pm

I had a complete shutdown of airflow in January 2015 at 140 ft with a braided hose. The hose was stamped 2008, used daily for about 4 years in Cozumel.

Lloyd Borrett - April 20th, 2018 at 4:53am

The DAN Alert Diver article titled 'Air Hoses: A Closer Look' has triggered some inquiries regarding material used in the construction of double braided flex hoses. We supply Miflex hoses and they ARE NOT constructed with an inner lining of Polyester-TPU. That material can undergo changes, called hydrolysis, which cause the rapid failure of the hose especially in hot and humid conditions.



Miflex branded hoses are constructed with an inner lining of Polyether-TPU. Some other braided flex hoses are constructed with an inner lining of High Syntactic Polyvinyl Chloride. Regardless, neither Polyether-TPU or HS-PVC is Polyester-TPU. In our long 10 year history with all the double braided Miflex hoses we've sold, we've never seen anything we think could be the hydrolysis problem described in the DAN Alert Diver article.



Miflex hoses are the real deal and we believe safer with longer life than rubber hoses. They are manufactured in Italy with more than thirty individual performance and safety automated tests. All Miflex hoses are designed to meet CE EN250 standards and are Nitrox Ready. But make sure you buy high quality, Miflex hoses, not cheap brand flexible braided hoses made from inferior materials.

DAN Medical Team - April 24th, 2018 at 11:36am

DAN does not promote or demote specific manufacturers' products. Our intention is to point out the fundamental reasons for failure and then to advise the diver as to what measures to take to remain safe.



Miflex themselves state that a 5-year or 500 dive count is what the diver should understand as the life span of the hose; of course assuming that there is no abrasion or other mechanical damage. This is their recommendation.



Miflex do indeed use poly-ether PU: this we determined when we found early onset degradation in hoses containing a poly-ester PU liner. They confirmed this although they also informed us that up to 2008, they had some doubts about the quality of the liner materials they used. After this date, they enhanced their quality control to make sure that the material used was indeed the poly-ether version.



Lastly, Miflex cooperated fully with our investigation and in fact both approved of the articles as well as being grateful for our publishing them.

Categories

 2020
 2019
 2018
 2016
immersion and bubble formation Accidents Acid reflux Acute ailments After anaesthesia Air Quality Air exchange centre Air hose failure Airway control Air Alert Diver Magazine Alternative gas mix Altitude changes Altitude sickness Aluminium Oxide Ama divers Amino acids Anaerobic Metabolism Annual renewal Apnea Apnoea Archaeology Arterial gas embolism Arthroscopic surgery Aspirin Aurel hygiene BCD BHP BLS BWARF Back adjustment Back pain Back treatment Backextensors Badages Bag valve mask Bahamas Balancing Bandaids Barbell back squat Barometric pressure Barotrauma Basic Life Support Batteries Bench press Benign prostate hyperplasia Beth Neale Black Blood flow Blood thinners Blue Wilderness Blurred vision Boat safety Bone fractures Bouyancy compensators Boyle's Law Boyle\'s Law Bradycardia Brain Breast Cancer Breath Hold Diving Breath holding Breath hold Breath-hold Breathing Gas Breathing gas contamination Breathing Breathold diving Broken bones Bruising Bubbleformation Buddy Exercise Buddy checks Buoyancy Burnshield CGASA CMAS CO2 COVID-19 COVID CPR Cabin pressure Caissons diseas Camera settings Cancer Remission Cancer treatments Cancer Cannabis and diving Cannabis Cape Town Dive Festival Cape Town CapeTown Carbon Monoxide Carbon dioxide Cardio health Cardiological Cardiomyopathy Chamber Safety Chamber science Charging batteries Charles' Law Charles\' Law Charles\\\' Law Charles\\\\\\\' Law Charles\\\\\\\\\\\\\\\' Law Charlie Warland Chemotherapy Chest compressions Chiropractic Chlorophll Citizen Conservation Cleaning products Coastalexcursion Cold Water Cold care ColdWater Cold Commercial diving Commercial schools Compressed Air Compressed gas Consercation Conservation Contaminants Contaminated air Coral Conservation Coral Reefs Coral bleaching Corals Core strength Corona virus Courtactions Crohns disease Crowns Crystal build up Crystallizing hoses Cutaneous decompression DAN Courses DAN Profile DAN Researchers DAN medics DAN members DAN report DCI DCS Decompressions sickness DCS theories DCS DEMP DM training DNA DReams Dalton's Law Dalton\'s Law Dalton\\\'s Law Dalton\\\\\\\'s Law Dalton\\\\\\\\\\\\\\\'s Law Danel Wenzel Dauin island Dean's Blue Hole Deco dives Decompression Illness Decompression Sickness Decompression Stress Decompression illsnes Decompression treatment Decompression Deep diving Deep water exploration Delayed Offgassing Dental Diaphragms Diseases Dive Chamber Dive Computer Dive Destinations Dive H Dive Industry Dive Instruction Dive Instructor Dive Medical Form Dive Medical Dive Pros Dive Research Dive South Africa Dive Training Dive Travel Dive accidents Dive buddies Dive computers Dive excursions Dive fitness Dive gear Dive heallth Dive health Dive medicines Dive medicine Dive operators Dive planning Dive safety Dive safe Dive staff DiveLIVE Diveleader training Diveleaders Diver Health Diver Profile Diver infliencers Diver on surface Divers Alert Diving Divas Diving Kids Diving Trauma Diving career Diving emergencies Diving emergency management Diving fit Diving guidelines Diving injuries Diving suspended Diving Dizziness Dolphins Domestic Donation Dowels Dr Rob Schneider Drysuit diving Drysuit valves Drysuits Dyperbaric medicines EAPs EAP Ear pressure Ear wax Ears injuries Eco friendly Education Electronic Emergency action planning Emergency decompression Emergency plans Emergency underwater Oxygen Recompression Emergency Enviromental Protection Environmental factors Environmental impact Environmental managment Equalisation Equipment care Evacuations Evacuation Evaluations Even Breath Exercise Exhaustion Extended divetime Extinguisher Extreme treatments Eye injuries FAQ Factor V Leiden Failures Fatigue Faulty equipment Female divers Fillings Fire Coral Fire Safety Firefighting First Aid Equipment First Aid Kit First Aid Training First Aid kits Fish Identification Fish Fitness Training Fitness to dive Fitness Flying Fractures Francois Burman Fredive Free Student cover Free diving Free flow Freedive INstructor Freedive Training Freediver Freediving performance Freediving Gas Density Gas consumption Gas laws Gas mixes GasPerformance Gases Gastoeusophagus Gastric bypass Gastroenterologist Gear Servicing Gordon Hiles Great White Sharks Gutt irritations HCV HELP HIRA HMS Britanica Haemorhoid treatment Hazard Description Hazardous Marine life Hazardous marinelife Health practitioner Heart Attack Heart Health Heart Rate monitor Heart rates Heart rate Heart Heat stress Helium Hepatitis C Hepatitus B High temperatures Hip strength Hip surgery Hippocampus History Hot Humans Hydrate Hydration Hydrogen Hydroids Hydrostatic pressure Hyperbaric Chamber Hyperbaric research Hyperbarics Hypothermia Hypoxia IdentiFin Immersion Immine systems In Water Recompression Indemnity form Indian Ocean Indonesia Inert gas Infections Infra red Imaging Injections Instinct Instruction Instructors Insurance Integrated Physiology International travel International Interval training Irritation Joint pain Junior Open Water Diver KZN South Coast Kidneys Kids scubadiver KwaZulu Natal Labour laws Laryngospasm Lauren Arthur Learning to dive Legal advice Legislation Leukemis Liability Risks Liability releases Liability Life expectancy Lifestyle Lightroom editing Live aboard diving Liver Toxicity Liver diseas Low blood pressure Low pressure deterioration Low volume masks Lung Irritation Lung function Lung injuries Lung squeeze Lung surgery Lung MOD Maintenance Malaria Mammalian Dive Response Mammalian effect Marine Biology Marine Scientists Marine conservation Marine parks Marinelife Masks Master scuba diver Maximum operating depth Medical Q Medical emergencies Medical questionaire Medical statement Medication Mehgan Heaney-Grier Mermaid Danii Mesophotic Middle ear pressure Mike Bartick Military front press Mixed Gas Mono Fins Mooring lines More pressure Motion sickness Mozambique Muscle pain Mycobacterium marinum Nausea Nautilus Neck pain Neurological assessments Nitrogen Narcosis Nitrogen build up Nitrox No-decompression Non-rebreather Mask Normal Air Nosebleeds O2 providers O2 servicing OOxygen maintenance Ocean Research Ocean pollution Oil contamination Open water divers Orbital implants Oronasal mask Osteonecrosis Out and about Outreach Oxygen Cylinder Oxygen Units Oxygen deficit Oxygen deicit Oxygen dificiency Oxygen ears Oxygen equipment Oxygen masks Oxygen supply Oxygen therapy Oxygen P J Prinsloo PFI PJP Tech Part 3 Partner Training Philippine Islands Philippines Phillipines Photography Physioball Physiology Physiotherapy Pills Pistons Planning Plastic Pneumonia Pneumothorax Poison Pollution Pool Diving Post-dive Pre-dive Predive check Preparation Prepared diver Press Release Professional rights Provider course Psycological Pulmanologist Pulmonary Bleb Pulmonary Edema Pulse Punture wounds Pure Apnea Purge RAID South Africa RCAP REEF Radio communications Range of motion Rashes Rebreather diving Rechargeable batteries. Recompression chamber Recompression treatment Recompression Recycle Reef Conservation Reef surveyors Regulator failure Regulators Regulator Remote areas Renewable Report incidents Rescue Procedure Rescue breathing Rescue breaths Rescue training Rescue Resume diving Return to diving Risk Assessments Risk assesments Risk assessment Risk elements Risk management SABS 019 SafariLive Safety Stop Safety SaherSafe Barrier Salty Wanderer Sanitising Sara Andreotti Saturation Diving Save our seas Science Scombroid Poisoning Scuba Air Quality Scuba Injury Scuba Instructor Scuba children Scuba dive Scuba health Scubalearners Sea Horses Sealife Shark Protection Shark Research Shark conservation Shark diving Sharks Shoulder strength Sideplank Signs and Symptoms Sit-ups Skin Bends Skin outbreak Skin rash Snorkeling Snorkels Social Distancing Sodwana Bay Solomon Islands South Africa Spinal pain Splits Squeezes Stability exercise Standars Stay Fit Stents Step ups Stepping up Stroke Submerged Sudafed Sulawesi Supplemental oxygen Surface supplied Air Surfaced Surgeries Surgery Suspension training TRavel safety Tabata protocol Talya Davidoff Tattoes Technical Diving The Bends The truth Thermal Notions Tides Tips and trick Tooth squeeze Transplants Travel smarter Travel tips Travel Tropical Coastal Management Tunnelling Tweezers Ultrsound Umkomaas Unconsciousness Underground work Underwater hockey Underwater photographer Underwater photography Underwater pho University of Stellenbosch Urinary retention. Vaccines Vagus nerve Valsalva manoeuvers Vape Vaping Vasopressors Vasvagal Syncope Venting Virus infections Volatile fuels Washout treatments Wastewater Watchman device Water Resistance Water Weakness Weigang Xu Weights West Papua Wet diving bell Wetsuit fitting Wetsuits White balance Wide angles Winter Woman in diving Woman Women In Diving SA Women in diving Work of Breathing Workout Wound dressings Wreck divers Wreck dive Wreckdiving Wrecks Yoga Youth diver Zandile Ndholvu Zoology abrasion acoustic neuroma excision air-cushioned alert diver altitude anemia antibiotics anticoagulants antiseptics bandages barodontalgia bent-over barbell rows bioassays body art breathing air calories burn carbon dioxide toxicity cardiovascular cerebrospinal fluid checklist chemo port child clearances closed circuit scuba currents cuts dead lift decompression algorithms decongestants decongestion dehydration dive injuries dive medicing dive ready child dive reflex dive tribe diver in distress diver rescue diver training dive diving attraction doctors domestic travel dri-suits drowning dry mucous membranes dry suits dry e-cigarettes ear spaces elearning electrolyte imbalance electroytes emergency action plans emergency assessment equalising equalizing exposure injuries eyes fEMAL DIVERS fire rescue fitnes flexible tubing frediving freedivers gas bubble gas poisoning gastric acid gene expression health heartburn histidine hospital humidity immersion and bubble formation immersion pulmonary edema (IPE jaundice join DAN knee longevity lower stress malaise marine pathogens medical issues medical procedures medical risk assesment medications mental challenge micro-organisims minor illness mucous membranes nasal steroids nasal near drowning nematocysts neurological newdivers nitrogen bubbles off-gassed operating theatre operations orthopeadic outgas pain perforation phillippines physical challenges pinched nerves plasters polyester-TPU polyether-TPU post dive posture preserve prevention psychoactive pulmunary barotrauma rebreather mask rebreathers retinal detachment risk areas safety stops saturation scissors scuba equipment scuba single use sinus infections smoking snorkeling. spearfishing sterilising stings strength sub-aquatic swimmers ears tattoo care tecnical diver thermal protection toxicity training trimix unified standards vision impaired warmers water quality